AbortAction
Structure
AbortAction(sError)
Parameters
| Parameter | Type | Description
| sError | String | The message that will be returned to the user through a modal dialog if the procedure is called. This message is optional pass an empyt string to skip a message. |
Description
This procedure is used to stop normal event execution (if applicable), and optionally return a message to the end user. Note that certain event triggers cannot stop event execution, by nature.
The following trigger actions CAN halt event execution (meaning they can respond to AbortAction):
Event Launch
Event Finish
Event Finish Incomplete
Add Equipment
Wizard Step Change
Barcode Read
Event Cancel
The following trigger actions CANNOT stop event execution:
Event Launch (end)
After Delete
Event Finish - Equip. Begin
Repair Parts Finish Loop
Charges Finish Loop
Charges Finish Loop
After Finish - Before Print
Add Equipment (End)
After Work Order Header Add
After Work Order Detail Add
After Work Order Creation
Add Equipment (After)
Attribute Button Click
Example
If LookupEquipmentCompany = 'ABC COMPANY' Then
AbortAction('ABC COMPANY is not a valid company for CALIBRATION event. Please choose another company.')
End If
AbortAction('')
Application Compatibility
IndySoft Calibration Management, IndySoft Commercial Lab Management, IndySoft Tool Management
Also See